Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37.829
Filtrar
1.
IEEE J Transl Eng Health Med ; 12: 340-347, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606389

RESUMO

OBJECTIVE: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the distal cement plug. This removal procedure often increases the risk of femoral fracture or perforation, haemorrhage and weakening bone due to poor drill control and positioning. Aim of this study was to design a novel drill guide to improve drill positioning. METHODS AND PROCEDURES: A novel orthopaedic drill guide was developed, featuring a compliant centralizer activated by a drill guide actuator. Bone models were prepared to assess centralizing performance. Three conditions were tested: drilling without guidance, guided drilling with centralizer activation held, and guided drilling with centralizer activation released. Deviations from the bone centre were measured at the entry and exit point of the drill. RESULTS: In the centralizing performance test, the drill guide significantly reduced drill hole deviations in both entry and exit points compared to the control ([Formula: see text]). The absolute deviation on the exit side of the cement plug was 10.59mm (SD 1.56) for the 'No drill guide' condition, 3.02mm (SD 2.09) for 'Drill guide - hold' and 2.12mm (SD 1.71) for 'Drill guide - release'. The compliant drill guide centralizer significantly lowered the risk of cortical bone perforation during intramedullary canal drilling in the bone models due to better control of the cement drill position. Clinical and Translational Impact Statement: The drill guide potentially reduces perioperative risks in cemented femoral stem revision. Future research should identify optimal scenarios for its application.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ortopedia , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação , Fêmur/cirurgia , Cimentos Ósseos/uso terapêutico
2.
Zhongguo Zhen Jiu ; 44(4): 395-399, 2024 Apr 12.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38621725

RESUMO

OBJECTIVES: To observe the effect of transcutaneous electrical acupoint stimulation (TEAS) on postoperative urinary function in elderly patients undergoing total hip arthroplasty (THA). METHODS: One hundred and eighty elderly patients undergoing unilateral THA without indwelling urinary catheters were randomly assigned to a TEAS group (90 cases, 3 cases dropped out, 4 cases were eliminated) and a sham TEAS group (90 cases, 1 case dropped out, 4 cases were eliminated). Both groups received fascia iliac block and subarachnoid block anesthesia under ultrasound guidance. The patients in the TEAS group were treated with TEAS at Zhongji (CV 3), Guanyuan (CV 4), and bilateral Huiyang (BL 35), Ciliao (BL 32) 30 minutes before anesthesia initiation, with dissperse-dense wave, frequency of 2 Hz/100 Hz, until 30 minutes after surgery. The patients in the sham TEAS group underwent the same procedure with the device applied at the same acupoints but without electrical stimulation. The incidence of postoperative urinary retention (POUR), time to first void, voiding threshold, urinary adenosine triphosphate (ATP) level, postoperative abnormal voiding status (bladder residual volume, re-catheterization rate, nocturia occurrence), and postoperative incidence of urinary tract infection (UTI) and prosthetic joint infection (PJI) were observed in both groups. RESULTS: The incidence of POUR in the TEAS group was lower than that in the sham TEAS group (P<0.05); the time to first void in the TEAS group was shorter than that in the sham TEAS group (P<0.05); the voiding threshold in the TEAS group was lower than that in the sham TEAS group (P<0.05); the urinary ATP level in the TEAS group was higher than that in the sham TEAS group (P<0.05); the bladder residual volume in the TEAS group was lower than that in the sham TEAS group (P<0.05); the nocturia occurrence in the TEAS group was lower than that in the sham TEAS group (P<0.05). However, there was no statistically significant difference in re-catheterization rate, incidence of UTI, and incidence of PJI between the two groups (P>0.05). CONCLUSIONS: TEAS could effectively reduce the occurrence of postoperative urinary retention and improve the postoperative urinary function in elderly patients undergoing THA, which might be related with increasing the urinary ATP level.


Assuntos
Artroplastia de Quadril , Noctúria , Estimulação Elétrica Nervosa Transcutânea , Retenção Urinária , Humanos , Idoso , Pontos de Acupuntura , Artroplastia de Quadril/efeitos adversos , Estimulação Elétrica Nervosa Transcutânea/métodos , Retenção Urinária/etiologia , Retenção Urinária/terapia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Trifosfato de Adenosina
3.
Med Eng Phys ; 126: 104159, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38621833

RESUMO

Generation of polyethylene wear debris and peri­prosthetic bone resorption have been identified as potential causes of acetabular component loosening in Total Hip Arthroplasty. This study was aimed at optimization of a functionally graded porous acetabular component to minimize peri­prosthetic bone resorption and polyethylene liner wear. Porosity levels (porosity values at acetabular rim, and dome) and functional gradation exponents (radial and polar) were considered as the design parameters. The relationship between porosity and elastic properties were obtained from numerical homogenization. The multi-objective optimization was carried out using a non-dominated sorting genetic algorithm integrated with finite element analysis of the hemipelvises subject to various loading conditions of common daily activities. The optimal functionally graded porous designs (OFGPs -1, -2, -3, -4, -5) exhibited less strain-shielding in cancellous bone compared to solid metal-backing. Maximum bone-implant interfacial micromotions (63-68 µm) for OFGPs were found to be close to that of solid metal-backing (66 µm), which might facilitate bone ingrowth. However, OFGPs exhibited an increase in volumetric wear (3-10 %) compared to solid metal-backing. The objective functions were found to be more sensitive to changes in polar gradation exponent than radial gradation exponent, based on the Sobol' method. Considering the common failure mechanisms, OFGP-1, having highly porous acetabular rim and less porous dome, appears to be a better alternative to the solid metal-backing.


Assuntos
Artroplastia de Quadril , Reabsorção Óssea , Prótese de Quadril , Humanos , Porosidade , Acetábulo/cirurgia , Metais , Polietileno , Reabsorção Óssea/cirurgia , Algoritmos , Desenho de Prótese , Falha de Prótese
4.
Med Eng Phys ; 126: 104142, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38621844

RESUMO

Total hip arthroplasty (THA) surgeries among young patients are on the increase, so it is crucial to predict the lifespan of hip implants correctly and produce solutions to improve longevity. Current implants are designed and tested against walking conditions to predict the wear rates. However, it would be reasonable to include the additional effects of other daily life activities on wear rates to predict convergent results to clinical outputs. In this study, 14 participants are recruited to perform stair ascending (AS), descending (DS), and walking activities to obtain kinematic and kinetic data for each cycle using marker based Qualisys motion capture (MOCAP) system. AnyBody Modeling System using the Calibrated Anatomical System Technique (CAST) full body marker set are performed Multibody simulations. The 3D generic musculoskeletal model used in this study is a marker-based full-body motion capture model (AMMR,2.3.1 MoCapModel) consisting of the upper extremity and the Twente Lower Extremity Model (TLEM2). The dynamic wear prediction model detailing the intermittent and overall wear rates for CoCr-on-XLPE bearing couple is developed to investigate the wear mechanism under 3D loading for AS, DS, and walking activities over 5 million cycles (Mc) by using finite element modelling technique. The volumetric wear rates of XLPE liner under AS, DS, and walking activities over 5-Mc are predicted as 27.43, 23.22, and 18.84 mm3/Mc respectively. Additionally, the wear rate was predicted by combining stair activities and gait cycles based on the walk-to-stair ratio. By adding the effect of stair activities, the volumetric wear rate of XLPE is predicted as 22.02 mm3/Mc which is equivalent to 19.41% of walking. In conclusion, in this study, the effect of including other daily life activities is demonstrated and evidence is provided by matching them to the clinical data as opposed to simulator test results of implants under ISO 14242 boundary conditions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Longevidade , Marcha , Fenômenos Biomecânicos , Falha de Prótese , Desenho de Prótese
6.
BMC Musculoskelet Disord ; 25(1): 255, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561701

RESUMO

BACKGROUND: Arthroplasty registries are rarely used to inform encounters between clinician and patient. This study is part of a larger one which aimed to develop an information tool allowing both to benefit from previous patients' experience after total hip arthroplasty (THA). This study focuses on generating the information tool specifically for pain outcomes. METHODS: Data from the Geneva Arthroplasty Registry (GAR) about patients receiving a primary elective THA between 1996 and 2019 was used. Selected outcomes were identified from patient and surgeon surveys: pain walking, climbing stairs, night pain, pain interference, and pain medication. Clusters of patients with homogeneous outcomes at 1, 5, and 10 years postoperatively were generated based on selected predictors evaluated preoperatively using conditional inference trees (CITs). RESULTS: Data from 6,836 THAs were analysed and 14 CITs generated with 17 predictors found significant (p < 0.05). Baseline WOMAC pain score, SF-12 self-rated health (SRH), number of comorbidities, SF-12 mental component score, and body mass index (BMI) were the most common predictors. Outcome levels varied markedly by clusters whilst predictors changed at different time points for the same outcome. For example, 79% of patients with good to excellent SRH and less than moderate preoperative night pain reported absence of night pain at 1 year after THA; in contrast, for those with fair/poor SHR this figure was 50%. Also, clusters of patients with homogeneous levels of night pain at 1 year were generated based on SRH, Charnley, WOMAC night and pain scores, whilst those at 10 years were based on BMI alone. CONCLUSIONS: The information tool generated under this study can provide prospective patients and clinicians with valuable and understandable information about the experiences of "patients like them" regarding their pain outcomes.


Assuntos
Artroplastia de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Resultado do Tratamento , Estudos Prospectivos , Dados de Saúde Coletados Rotineiramente , Dor/etiologia
7.
BMC Musculoskelet Disord ; 25(1): 248, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561717

RESUMO

BACKGROUND: Obesity represents an epidemic of rising numbers worldwide year after year. In the Orthopedic field, obesity is one of the major causes leading to osteoarthritis needing Total Joint Arthroplasty (TJA). Still, contextually, it represents one of the most significant risk factors for joint replacement complications and failures. So, bariatric Surgery (BS) is becoming a valuable option for weight control and mitigating obesity-related risk factors. This review of the literature and meta-analysis aims to evaluate periprosthetic joint infections (PJI) and surgical site infections (SSI) rates in patients who underwent TKA after BS compared to obese patients without BS. METHODS: Systematic review was performed according to Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines up to October 2023. We included longitudinal studies comparing obese patients who underwent total knee arthroplasty after bariatric surgery (study group) and obese patients who underwent TKA (control group). The surgical site infection and Periprosthetic joint infection rate were compared among groups using a meta-analytical approach. RESULTS: The online database and references investigation identified one hundred and twenty-five studies. PJI rate differed significantly among groups, (z = -21.8928, p < 0.0001), with a lower risk in the BS group (z = -10.3114, p < 0.0001), for SSI, instead, not statistically significance were recorded (z = -0.6784, p = 0.4975). CONCLUSIONS: The current Literature suggests that Bariatric Surgery can reduce infectious complications in TKA, leading to better outcomes and less related costs treating of knee osteoarthritis in obese patients.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Cirurgia Bariátrica , Osteoartrite do Joelho , Infecções Relacionadas à Prótese , Humanos , Artroplastia do Joelho/efeitos adversos , Infecção da Ferida Cirúrgica/etiologia , Cirurgia Bariátrica/efeitos adversos , Obesidade/complicações , Obesidade/cirurgia , Osteoartrite do Joelho/epidemiologia , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/complicações , Artrite Infecciosa/etiologia , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos
8.
J Orthop Surg Res ; 19(1): 206, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561763

RESUMO

BACKGROUND: Reports show a high complication rate when starting with the Direct Anterior Approach (DAA) in a supine position for hip arthroplasty. The DAA with the patient in lateral decubitus position may avoid this problem because it supposedly provides better visibility, especially on the femoral side. However, this approach did show a rather high complication rate during the adoption of the approach at 1 year follow up in our previous report. We were interested what the overall 7 year survival estimate would be and whether improvement could be seen with growing experience. METHODS: A cohort of patients undergoing total hip arthroplasty right from the start of applying the DAA in lateral decubitus position was analysed. RESULTS: In total 175 hip prostheses (162 patients) were evaluated. The 7-year survival estimate was 95.1%, 95 CI: 91.8-98.4%. In 6 of 8 revisions there was aseptic loosening of the stem. By dividing the cohort into 3 consecutive groups in time we did not see a significantly improving revision rate. CONCLUSIONS: In our experience, the adoption of the direct anterior approach in lateral decubitus position caused a relatively low 7-year survival estimate without an apparent decrease with growing experience, however given the low number of cases further research is needed to investigate the long-term risk of adopting a new approach.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Reoperação
9.
J Orthop Surg Res ; 19(1): 229, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584259

RESUMO

BACKGROUND: Pericapsular nerve group block (PENG) is an emerging regional anesthesia technique for hip surgery. However, its efficacy in total hip arthroplasty (THA) isn't well defined. We perform this meta-analysis aiming to assess the effect of Pericapsular nerve group block on pain control and morphine consumption in patients with total hip arthroplasty. METHODS: We searched four electronic databases (Pubmed, Embase, Cochrane Library, and Web of Science dated from 2018 to October 2023) for published eligible randomized controlled trials (RCTs) comparing PENG with placebo (no block/sham block) after THA. The outcome measurements consisted of pain score, opioid consumption, Time to first opioid, and postoperative complications. All data analyses were performed using STATA 12.0. RESULTS: Five RCTs comprising 808 participants were included. Our meta-analysis showed that there were significant differences between two groups in terms of pain score in PACU (WMD = - 0.598, 95% CI [- 0.886, - 0.310], P < 0.001), pain score at 6 h (WMD = - 0.614, 95% CI [- 0.835, - 0.392], P < 0.001) and time to first opioid (WMD = 5.214, 95% CI [4.545, 5.883], P < 0.001). However, no significant differences were revealed from the pain score at 24 h after THA (WMD = - 0.924, 95% CI [- 1.929, 0.081], P = 0.072). Meanwhile, the meta-analysis indicated that PENG significantly reduced 24-h opioid consumption (WMD = - 6.168, 95% CI [- 6.667, - 5.668], P < 0.001) and 48-h opioid consumption (WMD = - 7.171, 95% CI [- 8.994, - 5.348], P < 0.001). CONCLUSION: Pericapsular nerve group block was effective for pain control up to postoperative 6 h and extending the time to the first opioid after THA. Moreover, it reduced postoperative opioid consumption when compared with a placebo group. Due to the high heterogeneity of the pain score after 24 h and the low-quality evidence, more high-quality RCTs are required to draw a definitive conclusion about pain control.


Assuntos
Artroplastia de Quadril , Bloqueio Nervoso , Humanos , Analgésicos Opioides/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Nervo Femoral , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Bloqueio Nervoso/métodos
10.
Surg Infect (Larchmt) ; 25(3): 240-246, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38588520

RESUMO

Background: Total knee arthroplasty (TKA) is one of the most common inpatient and outpatient surgical procedures performed in the United States and is predicted to increase 401% by 2040. Surgical site infections (SSIs) at an incidence rate of approximately 2% are costly post-operative complications in TKA. Intra-operative surgical irrigants are used to decrease contaminating microbial bioburden within the surgical site to prevent SSI. The primary objective of this retrospective study was to evaluate the impact of a novel surgical irrigant called XPERIENCE® Advanced Surgical Irrigation (XP; Next Science, Jacksonville, FL) on SSI incidence in primary TKA performed at an ambulatory surgery center (ASC). Patients and Methods: Primary TKAs were performed at a free-standing ASC. The novel surgical irrigant was used intra-operatively to rinse away debris and micro-organisms from the surgical site. Retrospective data collation included SSI rates, complication rates, and re-admissions due to SSI within 90 days of index surgery. Results: Among the 524 primary TKA surgeries, one peri-prosthetic joint infection (PJI) was diagnosed within 90 days of index surgery and one superficial incisional SSI was diagnosed within 30 days of index surgery. The PJI was attributed to an exogenously acquired upper respiratory tract infection rather than due to the failure of intra-operative regimes. The 0.19% PJI incidence rate indicated significant efficacy of XP in decreasing PJI. An overall complication rate of 7.82% was noted with none of the complications associated with usage of the novel surgical irrigant. Conclusions: XPERIENCE is a promising intra-operative antimicrobial irrigant that can be easily incorporated into a broader infection prevention strategy.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Humanos , Estados Unidos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Estudos Retrospectivos , Artroplastia do Joelho/efeitos adversos , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Incidência , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/etiologia , Artroplastia de Quadril/efeitos adversos
11.
BMC Musculoskelet Disord ; 25(1): 259, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566097

RESUMO

BACKGROUND: Modular neck femoral stems are advantageous because they can accurately restore the ideal hip geometry using various options in terms of offset, length, and version. However, there are concerns regarding junctional problems. Despite several reports on such issues, there is a lack of study on mid- to long-term results of these stems. The current study evaluated the mid-term results of patients who underwent primary total hip arthroplasty using a titanium-titanium (Ti-Ti) modular neck femoral stem. METHODS: In total, data on 47 hips (42 patients) that could be followed-up for ≥ 5 years after primary total hip arthroplasty using the Ti-Ti modular neck femoral stem from 2011 to 2015 were reviewed. There were 22 male and 20 female patients, and their mean age was 56.3 (range: 31-76) years. The mean follow-up period was 8 (range: 5-12) years. Functional and radiological outcomes, complications, and reoperations were investigated. In addition, we conducted a comparative analysis of the outcomes between those who underwent surgery using the Ti-Ti modular neck femoral stem and 41 hips (35 patients, 19 males and 16 females) that underwent primary total hip arthroplasty using nonmodular femoral stems as a control. RESULTS: In all Ti-Ti cases, the mean Harris Hip Scores were 50.6 (range: 6-59) preoperatively and 92.7 (range: 78-99) at the last follow-up (P < 0.001). Regarding the neck component's modularity, straight neck components were used in all Ti-Ti cases, and an anteverted or a retroverted neck was not used in any case. Stem revision was performed in one hip due to aseptic loosening. One hip underwent open reduction and internal fixation due to periprosthetic fracture without stem loosening. There were no cases of osteolysis and periprosthetic joint infection and clinically detectable junctional problems. The stem survival rate, with any stem revision as the endpoint, at 12 years was 96.6%. No significant difference was observed in the functional and radiological outcomes beween the Ti-Ti and nonmodular groups. CONCLUSIONS: The Ti-Ti modular neck femoral stem had comparable results with broadly used nonmodular femoral stems; hence, it can be a reliable option in primary total hip arthroplasty. However, in terms of the modularity itself of the modular neck femoral stem, whether the modular neck femoral stem is useful in uncomplicated primary total hip arthroplasty is unclear.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Titânio , Desenho de Prótese , Estudos Retrospectivos , Reoperação , Seguimentos , Falha de Prótese
12.
Artigo em Inglês | MEDLINE | ID: mdl-38569087

RESUMO

BACKGROUND: Little is known about the effect of surgical approach on return to braking after total hip arthroplasty (THA), and few studies have investigated braking after THA with modern surgical techniques and rehabilitation protocols. METHODS: In a prospective comparative design, we enrolled 65 patients who received right-sided primary THA at our institution from April 2018 through March 2020, 34 with a direct anterior approach (DAA) and 31 with a posterior approach (PA). Braking tests measuring brake reaction time (BRT) and brake pedal depression (BPD) were administered to patients preoperatively and at 1, 2, and 4 weeks postoperatively using a realistic driving simulator. BRT and BPD were compared between groups and preoperatively versus postoperatively using mixed-effects models. RESULTS: Preoperative BRT averaged 638 msec in the DAA group and 604 msec in the PA group (P = 0.31). At 1 week postoperatively, the DAA group had significantly prolonged BRT compared with preoperatively (694 msec, P = 0.02). No significant difference was observed in the PA group (633 msec, P = 0.31). Both groups had returned to baseline by 2 weeks, and both had significantly faster BRT at 4 weeks compared with preoperatively (583 msec for DAA, P = 0.01; 537 msec for PA, P < 0.001). BPD was similar between groups, and there were no significant differences between preoperative and postoperative BPD at any time point. CONCLUSIONS: With modern surgical techniques, BRT after right-sided THA returns to baseline levels approximately 2 weeks after surgery. There seems to be a quicker return to preoperative BRT observed in patients with a PA.


Assuntos
Artroplastia de Quadril , Condução de Veículo , Humanos , Artroplastia de Quadril/métodos , Estudos Prospectivos , Tempo de Reação , Complicações Pós-Operatórias
13.
Sci Rep ; 14(1): 8332, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594498

RESUMO

Augmented reality (AR) has been used for navigation during total hip arthroplasty (THA). AR computed tomography (CT)-based navigation systems and AR-based portable navigation systems that use smartphones can also be used. This study compared the accuracy of cup insertion during THA using AR-CT-based and portable AR-based navigation systems. Patients with symptomatic hip disease who underwent primary THA in the supine position using both AR CT-based and portable AR-based navigation systems simultaneously between October 2021 and July 2023 were included. The primary outcome of this study was the absolute difference between cup angles in the intraoperative navigation record and those measured on postoperative CT. The secondary outcome was to determine the factors affecting the absolute value of the navigation error in radiographic inclination (RI) and radiographic anteversion (RA) of the cup, including sex, age, body mass index, left or right side, approach, and preoperative pelvic tilt. This study included 94 consecutive patients. There were 11 men and 83 women, with a mean age of 68 years. The mean absolute errors of RI were 2.7° ± 2.0° in the AR CT-based and 3.3° ± 2.4° in the portable AR-based navigation system. The mean absolute errors of RA were 2.5° ± 2.1° in the AR CT-based navigation system and 2.3° ± 2.2° in the portable AR-based navigation system. No significant differences were observed in RI or RA of the cup between the two navigation systems (RI: p = 0.706; RA: p = 0.329). No significant factors affected the absolute value of the navigation errors in RI and RA. In conclusion, there were no differences in the accuracy of cup insertion between the AR CT-based and portable AR-based navigation systems.


Assuntos
Artroplastia de Quadril , Realidade Aumentada , Prótese de Quadril , Cirurgia Assistida por Computador , Masculino , Humanos , Feminino , Idoso , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X , Cirurgia Assistida por Computador/métodos , Acetábulo/cirurgia
14.
BMC Musculoskelet Disord ; 25(1): 276, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600475

RESUMO

BACKGROUND: Traditional total hip arthroplasty (THA) using the direct anterior approach (DAA) requires a hip extension. This study aimed to compare the clinical outcomes of patients undergoing THA with DAA using either the no hip extension (NHE) or the traditional hip extension (THE) strategy. METHODS: A retrospective analysis of demographics, clinical and radiological outcomes, and occurrence of complications was performed using data from 123 patients treated between January 2020 and November 2021. The patients were categorised into two groups: NHE (84 patients) and THE (39 patients). RESULTS: The NHE group exhibited shorter operative time and had more male participants with higher ages. Comparable outcomes were observed in the visual analogue scale, Harris Hip, and Oxford Hip scores at the final follow-up. Furthermore, complications were observed in the NHE and THE groups, including two and one greater trochanteric fractures and three and one transfusions, respectively. CONCLUSIONS: Compared to the THE, employing the NHE strategy during THA with DAA in elderly and young female patients resulted in comparable clinical outcomes with several advantages, such as favourable surgical time. The NHE method also exhibited good safety and effectiveness. Therefore, the NHE strategy may be a favourable option for elderly and young female patients.


Assuntos
Artroplastia de Quadril , Humanos , Masculino , Feminino , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Resultado do Tratamento , Radiografia , Duração da Cirurgia
17.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): 108-120, Mar-Abr. 2024. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-231887

RESUMO

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Fraturas do Quadril , Quadril/cirurgia , Espanha , Epidemiologia Descritiva , Estudos Prospectivos , Procedimentos Ortopédicos , Traumatologia
18.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T108-T120, Mar-Abr. 2024. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-231888

RESUMO

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Fraturas do Quadril , Quadril/cirurgia , Espanha , Epidemiologia Descritiva , Estudos Prospectivos , Procedimentos Ortopédicos , Traumatologia
19.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T121-T127, Mar-Abr. 2024. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-231890

RESUMO

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Assuntos
Humanos , Masculino , Feminino , Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Fraturas do Quadril , Quadril/cirurgia , Espanha , Epidemiologia Descritiva , Estudos Prospectivos , Procedimentos Ortopédicos , Traumatologia
20.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 455-460, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632066

RESUMO

Objective: To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods: The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results: The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (-1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation ( P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation ( t=-7.269, P<0.001). Conclusion: AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Masculino , Feminino , Humanos , Idoso , Falha de Prótese , Reoperação , Estudos Retrospectivos , Inteligência Artificial , Seguimentos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Acetábulo/cirurgia , Complicações Pós-Operatórias , Luxações Articulares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...